Voltas Air Conditioner Error Code

Voltas Air Conditioner Error Code




Voltas Air Conditioner Error Code

SI NO. MODELS MOLE NUMBER PROBLEMS
1 VERTIS ELUTE
VERTIS ELITE (G)
4551031,
4551032,
4551031,
4551034,
45511149
E 1 AIR SENSOR DEFECTIVE
E 3 COIL SENSOR DEFECTIVE
E 4 BLOWER MOTER DEFECTIVE
E 1 BOTH SENSOR DEFECTIVE
E6 OVER CURRENT PROTECTION
2 VERTIS PLUS
VERTIS ELITE
VERTIS PLUS
VERTIS ELITE
4501006, 4550965, 4550966, 4551090, 4551070, 4551091, 4551071, 4551156, 4551157, 4551147, 4551148, F7 AIR SENSOR DEFECTIVE
F8 COIL SENSOR DEFECTIVE
F6 BLOWER MOTER DEFECTIVE
F7 BOTH SENSOR DEFECTIVE
3 VERTIS GOLD
VERTIS PREMIUM
VERTIS ELITE (G)3 STAR
4551134, 4551135, 4551136, 4551073, 4551119, 4551120, 4551133, 4551158, F1 AIR SENSOR DEFECTIVE
F2 COIL SENSOR DEFECTIVE
H6 BLOWER MOTER DEFECTIVE
E 5 OVER CURRENT PROTECTION
4 VERTIS PLUS
VERTIS PLUS (S)
4551027,4551028, 4551036, 4551037, 4551067, 4551068, 4551152, 4551153, 45511547, 4551155, E 2 AIR SENSOR DEFECTIVE
E 3 COIL SENSOR DEFECTIVE
E 5 BLOWER MOTER DEFECTIVE
5

ELITE (S) NEW

4551146,4551147 Red light BILINK & TIMER LED BILINK

Air Sensor Defective
COIL SENSOR FAULT

6

VERTIS GOLD

4551080, 4551081, 4551141, 4551142, GERRN LED BILINK TIMER LED ORANGE GLOWS

AIR SENSOR & COIL SENSOR DEFECTIVE
BLOWER MOTER DEFECTIVE,
AFTER 45 SECOUND BLOWER & COMPRESSOR
SWITCHES OFF

7 VERTIS CLASSIC 4551144, 4551145 TIMER LED BILINKS, & RUN LED BILINKS

AIR SENSOR DEFECTIVE
COIL SENSOR DEFECTIVE

8 VERTIS PLUS & PREMIUM
WINDOW
4010965, 4010966 4010967, 1010968 Er BOTH SENSOR DEFECTIVE
Er AIR SENSOR DEFECTIVE
En COIL SENSOR DEFECTIVE

Voltas Air Conditioner Error Code




Voltas Air Conditioner Error Code

Voltas Inverter Air Conditioner Error Codes



EE Indoor Machine EE Fault
E0 outdoor EE faults
E1 Indoor Fan Fault
E2 indoor fan zero-crossing detection abnormal
E3 Indoor Coil Fault and Sensor Fault
E4 indoor ambient temperature sensor fault
E5 Fan Operation Error
E6 Indoor and outdoor machine communication faults
E8 outdoor communication fault
F1 F1 compressor abnormal start
F2 compressor Step accidentally
F3 IPM Module Fault
F4 Compressor Shell Roof Malfunction / Safety
F5 discharge temperature sensor faults
F6 segment temperature sensor defect
F7 outdoor coil temperature sensor fault
F8 outdoor ambient temperature sensor faults
F9 outdoor DC fan fault
P1 Outdoor Machine AC Current Protection
P2 Compressor Phase Current Protection
P3 outdoor unit over- or high-low AC voltage protection
P4 DC voltage over-high or over-low voltage protection
P5 IPM ultra-high temperature protection
P6 discharge temperature over-heat protection
P7 Cooling Indoor Coil Anti-Cold Protection
P8 cooling outdoor coil overheat protection
P9 heating overheats indoor coil protection
PC cooling outdoor ambient temperature low-security
PH heating outdoor high temperature protection at high temperature
L1 drive bus voltage over-protection
L2 drive bus voltage over-low protection
L3 drive phase current overload fault
L4 phase current sampling abnormal
U1 IPM over current protection
U3 Compressor Over Current Protection
U4 Over Voltage Protection
U5 Low Voltage Protection
U7 Over Speed ​​Protection

Voltas Air Conditioner Error Code

voltas tower ac

Voltas Venture Slimline Tower AC Error Codes

E1 indoor unit room temperature sensor problem
E2 Trouble of indoor unit pipe temperature sensor
E3 PG motor trouble
E5 wired controller communication failure
E6 EEPRO of indoor unit error
1E trouble and external unit room temperature sensor
2E Trouble with outdoor unit pipe temperature sensor
3E exhaust sensor problem
4E EEPRO of indoor unit error (outdoor unit). Replace outdoor unit module board
8E PFC troubles. Replace outdoor unit module board
H1 Automatic Defrosting
H3 stop for compressor overload protection
H4 Overload Protection
H5 Stop for IPM Module Security
H6 PG motor does not operate (indoor fan motor)
HC PFC Overcurrent Malfunction
L9 High protection of power
LP Indoor and Outdoor units match with each other
PH high voltage protection
PL low voltage protection
C5 jumper cap malfunction

Share and Enjoy !

0Shares
0

Add a Comment

Your email address will not be published. Required fields are marked *