AEG washing machines Error codes

AEG washing machines Error codes

washing machin error
AEG L99695HWD Washine Machine, AEG washing machines Error codes

AEG washing machines Error codes

E00 no error

There is no error

E11 does not fill water in the drum during the washing cycle. (The time allotted to the Bay of Water has expired, and the required amount of water has not arrived.)

The water supply tap in the washing machine is closed.

There is no water pressure or it is very weak.

The washing machine drain hose is not connected correctly.

The water valve of the washing machine is faulty. To eliminate this, you need to replace the washing water valve in the washing machine or clean the filter screen.

Washing machine pressure switch is faulty. To solve the problem, you need to change the pressure switch in the washing machine or clean the hydraulic system.

The wiring or terminals of the washing machine are faulty.

The control module of the washing machine is faulty. This requires repair (re-soldering, re-flashing) or replacement.

E12 It is difficult to fill water in the washing machine during the drying method.

Module is faulty. Washing machine modules require repair or replacement.

There is a malfunction in the wiring of the washing machine. It is necessary to find a breakage, replace the damaged wire or repair it.

The hydraulic system of the washing machine presostat is faulty. Replacement of pressure switch is required.

The electrical valve of the washing machine is faulty. Solenoid valves need to be replaced.

Insufficient water pressure in the apartment pipeline. Check shut-off valve.

There is a sprout. To correct the problem, check that the drain hose is installed correctly.

AEG washing machines Error codes

E13 water leak from washing machine.

The water pressure is unacceptably low for this model of washing machine. It is necessary to check the water supply faucet, take measures to restore normal pressure in the apartment’s water supply.

The fill valve is faulty. Replacement of priming valve is required.

The hydraulic system of the pressure switch is faulty. Replacement of pressure switch is required.

E21 water drainage in the washing machine is difficult (no water has been removed from the tank within 10 minutes).

The drain hose of the washing machine is closed or bent. Drain hose must be cleaned or replaced.

Washing machine filter is full. It is necessary to eliminate the blockage in the filter of the pump.

The drain pump of the washing machine is broken. The drain pump must be replaced.

Defective Presostat Washing Machine. It is necessary to change the pressure switch.

The main circuit board of the washing machine is faulty. Washing machine module requires repair

E22 drainage of water in the washing machine is difficult (the pump does not pump water at the cycle between the pressure switch and the boiling point level (error exists more than 60 seconds).

The drain pipe, which goes from the washing machine to the sewer, is climbed or bent. To remove obstruction of the drain hose of the washing machine, it is necessary to replace the sensor.

There were faults in the electrical wiring on the part of the presostat circuit – to identify and eliminate faults.

The pressure sensor is not working properly – replace the pressure switch tube.

AEG washing machines Error codes

E35 There was water flow in the tank of the washing machine.

The electric current to fill the water was broken – to replace the solenoid valve.

There was a malfunction in the hydraulic system of the pressure switch or the pressure switch itself failed – clean the hydraulic system or replace the pressure switch.

The control module has failed – it is necessary to repair or replace the module.

AEG washing machines Error codes

E36 malfunction of heater safety level sensor (АВ S) The sensor of the heater’s protection level has come to a fault – replace the sensor.

E37 Defective Water Level Sensor (L1 S) Defective Water Level Sensor – Replace the sensor.

E38 Blocking the pressure receiver in the  pressure switch (the water level in the tank does not change when the SMA drum rotates for at least 30 seconds).

There was a malfunction in the hydraulic system of the presostat or the pressure switch itself became unusable – clean the hydraulic system (clean the presostat tube) or replace the pressure switch.

E39 faulty water level sensor (HV1 S) in tank

Overflow level sensor entered fault – replace sensor

E41 The door is not locked.

There was a malfunction in the wiring of the washing machine – check the contacts of the hatch lock.

If the door is not securely locked due to a user fault, the door must be tightened again.

E42 door closing problem.

The hatch latch had a mechanical defect – replace the latch or clean its contacts.

To replace UBL – hatch blocking device has failed.

E43 faulty triac of power supply for the door hatch delay device.

There was a malfunction in the wiring of the washing machine – check the contacts of the hatch lock.

The locking device for the hatch has failed – to change the UBL or to change the triac.

E44 AGR door lock reading violation

There was a malfunction in the wiring of the washing machine – check the contacts of the hatch lock.

The hatch closing sensor has failed – the sensor must be replaced.

E45 Violation of the door lock reading process (the voltage at the input of the microprocessor does not match the original data).

The hatch locking device has malfunctioned – to put the UBL or control trike on the controller.

The control module has failed – required to repair or replace the electronic module.

E51 The drive motor control circuit is faulty.

The control triac was a short circuit of the drive motor – replace the triac located in the controller unit or check and maintain the contacts of this section of the circuit.

E52 There is no signal for the taco generator of the CMA engine (the signal does not reach the controller).

There was a malfunction in the wiring of the washing machine on the section of the TACHO series.

The tachogenerator of the engine of the washing machine has failed – fix the refrigerator or replace the electric motor

E53 Motor Drive Triac Control Circuit Fault

The wiring of the circuit section of the controller is defective – to detect and repair faults in the wiring.

Failure of electronic controller is to replace electronic controller

E54 Reverse motor relay contact groups malfunction. The reverse relay has failed – to replace the relay or the electronic controller completely.

E55 motor circuit fault.

There was a break in the winding of the engine – to rewind the engine or to completely replace the ED.

Wiring violation in motor control section – Check wiring, contacts, if necessary, replace faulty wiring.

E56 There is no signal from the tachometer generator (the signal does not come on for 15 minutes). Fuel generator failed – required to repair or completely replace the entire unit

E57 The requested current from the inverter is more than 15A readings

There was a malfunction in the wiring of the washing machine – check the inverter circuit.

The washing machine’s inverter has gone bad – replace the board or repair it.

The winding of the electric motor of the washing machine is burnt – to replace the engine.

E58 The requested current from the inverter has readings greater than 4.5 A, but less than 15 A.

The engine of the washing machine works with overload – check the rate of loading the tank with linens.

There was a malfunction in the wiring of the washing machine – check the inverter circuit.

The washing machine’s inverter has gone bad – replace the board or repair it.

To replace the engine – the motor has failed.

E59 The tachometric signal is absent for three seconds.

There has been a fault in the wiring in the motor-inverter section – the wiring needs to be replaced.

The washing machine’s inverter has gone bad – replace the board or repair it.

The electric motor has failed – to replace the engine or replace the tachometer generator.

E61 Water does not heat up to the desired temperature. The heat is slow

There was a malfunction in the wiring in the TEN control circuit – find the defective area and replace it.

The temperature sensor of the washing machine has failed – replace the temperature sensor.

I came to mistake TEN – replacing the heater.

There was a malfunction in the main module work of the washing machine – to repair the module or replace it.

E62 is an excess of water (the temperature is over 88 ° C for 5 minutes)

Defective Wiring Harness Control Unit or TEN – Install a new wiring.

A temperature sensor malfunction has occurred – install a new SMA thermal sensor.

There was a flaw in the TEN’s control circuit – if necessary, to replace the burned parts, check the dynamics of the circuit.

The control module has failed – it is necessary to repair or replace the module.

E66 faulty power relay resistor on the control board TEN (there is a discrepancy between the reading and relay status). There was a flaw on the printed circuit board of the TEN control unit – replace the burned parts.

E68 Current leakage occurs in the ground through the heater (the value of the mains voltage is different from the mains voltage). There was a leakage current between the resistor and the mass – check the wiring for breakdown voltage or replace the TEN

E69 resistor is in a passive state

There was a malfunction in the wiring of the washing machine – check the mobility of the control card and its contacts.

Washing heating stop is disconnected (thermal fuse has opened) – replace defective part.

There was a defect on the main electronic board – to repair the board.

E71 NTC probe malfunction for washing (short circuit inside cabinet contact or seamless opening of device contacts).

There was a malfunction in the wiring from the NTC series – to eliminate faults in the wiring (eliminating open or short circuits).

A temperature sensor malfunction has occurred – install a new SMA thermal sensor.

Control module has failed – it is necessary to repair or replace the module

E72 The NTC probe of the drying condenser is faulty (the voltage value of this device is out of range when the contact opens).
To eliminate defects in wiring – there was a malfunction in the wiring in the NTC series section.

There is a malfunction in the drying sensor or condenser probe – replace faulty parts and components.

There was a malfunction in the main electronic board – replacing the burned parts, repairing the board.

E73 NTC check of drying pipeline has failed (voltage value is outside normal range).

To eliminate defects in wiring – there was a malfunction in the wiring in the NTC series section.

There is a malfunction in the drying sensor or condenser probe – replace faulty parts and components.

There was a malfunction in the main electronic board – replacing the burned parts, repairing the board.

Progress of heating phase during drying – NTC contacts are sealed.

E74 Washing, in conduct of NTC investigation for violation

To eliminate defects in wiring – there was a malfunction in the wiring in the NTC series section.

There is a malfunction of the drying sensor or capacitor probe – replace faulty parts and components or correct the position of the sensor.

There was a malfunction in the main electronic board – replacing the burned parts, repairing the board.

Progress of heating phase during drying – NTC contacts are sealed.

E82 Wrong switch status when starting and restarting. The main electronic board malfunction is – replacing the burned parts, to repair the contact tracks.

E83 A switch error occurred. The main electronic board malfunction is – to repair contact tracks, replace burnt parts or completely replace the unit.

E91 A communication error has occurred between the visualization board.

There was a break for the wiring visualization board – replace or repair the damaged wire.

There is a malfunction of the visualization board of the washing machine.

E92 The is a mismatch between the main electronic board and the visualization board (incompatible version). . Stopped an incorrect electronic control / visualization board (does not match the model) – install the required board

E93 An error occurred in the hardware configuration. There was a defect on the PCB of the control module – to repair the board or replace the entire module.

E94 A configuration error has occurred in the wash cycle. There was a flaw in the control module board (misconfiguration data) – to repair the board or replace the control module.

E95 There is a communication error between the microprocessor and the EEPROM. The main electronic board had one defect – to repair the board or replace the control module.

E96 configuration error when connecting the controller to external components. Incorrect assembly – check the connection of external components to the controller.

E97 There was a discrepancy between the set operating mode and cycle configuration. There was a flaw in the main electronic board (misconfiguration data) – repair the card or replace the control module.

E98 There was a communication error between the motor control board (main electronics). There is incompatibility between the electronic board and the inverter – to install the necessary equipment or replace the main board.

E99 The is an incompatibility between the electronic board and the inverter – to install the necessary equipment or replace the main board.

Sound block malfunction – The sound block must be replaced.

There were violations in the wiring in the sections of the circuit of the sound block – check the wiring harness, contacts and connectors of equipment, replace faulty wiring

E3A There was an error in the operation of the resistor relay (it misreads the relay of the heating element). There was an error in the operation of the resistor relay (it misreads the relay of the heating element).

E5A The inverter cooling coil has an increased temperature (the cycle closes when the door is closed).

If the defect is caused by a defect appearing in the inverter board (NTC is open) – Replace the board.

If the elevated temperature is due to continuous cycles or atmospheric conditions, the equipment should be allowed to cool.

E5B The voltage at the inverter input went below 175 V.

To eliminate defects in wiring – there was a malfunction in the wiring in the NTC series section.

Inverter board malfunction – replace board.

E5C The input voltage of the inverter board is very high (greater than 430 V). Inverter board malfunction – replace board.

E5D A communication error occurred between the inverter and the main board (FCV cannot receive and / or send messages within 2 seconds).

Interference on line – restart AGR.

There was a malfunction in the internal wiring of the AGR – to eliminate defects in the wiring.

There is a malfunction of the main board or inverter board – to supply serviceable equipment.

E5E A communication error has occurred between the main board and the inverter.

To eliminate faults – there was a wiring malfunction in the mainboard-inverter section.

There is an inverter board malfunction – to supply a serviceable board.

Main board malfunction – to provide a serviceable board

E5F The does not start with the motor inverter board (the FCV control board continuously requests configuration parameters).

The main board-inverter section had a wiring defect – to eliminate the defect.

There is an inverter board malfunction – to supply a serviceable board.

The main board malfunction is – to install a serviceable board.

E9A Software problems between speakers and input / output electronics. The control unit has encountered a malfunction – the control module needs to be replaced.

E9B A communication error has occurred between the microprocessor and flash memory of the card. There was a flaw in the work of the visualization board – clearing the contacts of the equipment or replacing the visualization board.

E9C An hardware configuration error has occurred. A defect has occurred in the visualization board – clear the device contacts or replace the visualization board.

E9D There is a flaw in the operation of the visualization board – clear device contacts or replace the visualization board. There was a flaw in the work of the visualization board – clearing the contacts of the equipment or replacing the visualization board.

E9F communication error occurred between main board and CMA inverter board

To eliminate faults – there was a wiring malfunction in the mainboard-inverter section.

There is an inverter board malfunction – to supply a serviceable board.

The main board malfunction is – to install a serviceable board.

EA1 The drum (DSP) has an incorrect position.

There was a mechanical damage in the drive belt of the engine of the washing machine – to replace a new belt.

The internal wiring of the AGR had a malfunction – to eliminate defects.

The main board malfunction is – to install a serviceable board.

There was a malfunction in the operation of the DSP sensor – to replace the sensor.

Status is an advance of stage – inspecting and repairing the BU board.

EA2 The detection error in the DS2 system is a problem with the main board – to install a working board.

EA3 is the main board malfunction – to provide a serviceable board.

The DSP was at fault – you need to replace the DSP.

The internal wiring of the AGR had a malfunction – to eliminate defects.

The main board malfunction is – to install a serviceable board.

Mechanical damage occurred to the drive belt – to replace the drive belt.

EA4 is a DSP flaw

The DSP was at fault – you need to replace the DSP.

The internal wiring of the AGR had a malfunction – to eliminate defects.

There is a malfunction in the control unit – to install a serviceable main board or replace the entire unit

EA5 faulty thyristor DSP. The main board malfunction is – to install a serviceable board.

EA6 DSP door opening fault.

There was no fixation of the lid in the closed state – check the mechanical latch, if necessary, install a new latch.

The main board malfunction is – to install a serviceable board.

EB1 power frequency mismatch values. There is no normal voltage in the apartment network of apartments – take measures to restore normal parameters.

EB2 supply voltage is high. There is no normal voltage in the apartment network of apartments – take measures to restore normal parameters.

EB3 is a low voltage supply for the mains. . There is no normal voltage in the apartment’s apartment network – take measures to restore the normal parameters

EBE A fault occurred in the protection circuit relay. Replace the electronic unit.

EBF An error has occurred in the circuit recognition device. Replace the electronic unit.

EC1 Replace the electronic unit.

There was a malfunction in the internal wiring of the AGR – to eliminate defects in the wiring.

Electrovelve failed – to replace the solenoid valve.

There is a malfunction of the main board – to install a new board.

EC2 The water transparency sensor is faulty. It is necessary to replace the transparency sensor.

EC3 There are problems with the weight sensor (signal is missing completely or it is outside the acceptable range).

There was a malfunction in the internal wiring of the AGR – to eliminate defects in the wiring.

Wet sensor of the washing machine malfunctioned – installed new sensor.

The main board malfunction is – to make the replacement board.

AEG washing machines Error codes

Ed1 A communication error has occurred between the CCM board and the main board of the control unit.

There was a malfunction in the internal wiring between the CCM board and the main board – you need to eliminate the wire brake, replace the faulty wire.

There is a malfunction in the SSM card – install a new card.

BU’s main board comes to a fault – install a new card

Ed2 drying resistor relay has a malfunction

There was an internal wiring fault between the CCM board and thermostats – fixing the wiring.

Washing machine thermostats have become unusable – replace thermostats.

There is a malfunction in the SSM card – install a new card.

The main board is in trouble. BU – Install a new board.

E d3resistor relay has a fault

Drying Number 2

There was an internal wiring fault between the CCM board and thermostats – fixing the wiring.

Washing machine thermostats have become unusable – replace thermostats.

There is a malfunction in the SSM card – install a new card.

Main board malfunction

Ad4 The relay that switches power between the washing resistors and does not work correctly by drying on the circuit board.

There was a malfunction in the internal wiring inside the drying unit – fixing the wiring.

There is a malfunction in the SSM card – install a new card.

The main board is in trouble.

AEG washing machines Error codes

C0 The error in the water filling system is a malfunction of the pressure switch – it is necessary to clean the hydraulic system of the pressure sensor or completely replace the entire presostat assembly.

C1 does not pass water.

There was a malfunction in the water inlet valve – clean the filter grid or replace the solenoid valve.

The apartment’s plumbing had low water pressure – take measures to restore normal pressure.

The controller has failed – replace the AGR controller.

C2 does not lock. The lockout device had one flaw – to repair or replace the UBL.

C3 pumping system error.The pump filled with water is in trouble – replace the pump.

The module had a defect on the main board – to repair the board or replace it.

C4 problems with pumping water out (drainage is slow). The problem of draining water (drainage is slow).

C5 The main motor sensor overheats. Motor winding malfunction – repair winding, or replace sensor, or replace motor.

C6 problems in the water injection system (water does not fill the tank to the required level). Problems with the water injection system (water does not fill the tank to the required level).

C7 water is not heated to the correct temperature. There was a heating element malfunction – replace the heater.

C8 heating element was malfunction – replace heater. There was a temperature sensor malfunction – you need to replace the thermostat.

C9 The engine does not develop the required rotation speed. One problem was tahodchika – you need to correct the device or replace the entire ED unit.

CF The system does not receive a signal to start working. EEPROM memory crash – you must restart the machine or check the contacts of the controller

CD The system does not receive a signal to begin operation (the hatch door is not closed). The system does not receive a signal to begin operation (the hatch door is not closed).

 

washing machin error
AEG washing machines Error codes

ALSO READ THIS

AEG User & Service Manuals PDF

Carrier Air Conditioner Error Codes

Share and Enjoy !

Shares

Add a Comment

Your email address will not be published. Required fields are marked *