Aux Air Conditioner Error Codes

AUX Air Conditioner Error Codes

Aux Air Conditioner Error Codes


1. HSF (Y) HV(Y) HS(Y) HSA(Y) HSB(Y) HVA(Y) digital display for the series ac error codes:

Error source = PG motor response is abnormal
Display Mode = E4
Performance precedence level = 1

Error source = Plastic Temp Sensor is abnormal.
Display Mode = E1
Performance precedence level = 2

Error source = Copper Temp Sensor is abnormal (indoor)
Display Mode = E3
Performance precedence level = 3

Error source = copper temp sensor is abnormal (outdoor)
Display Mode = E2
Performance precedence level = 4
H (excluding KFR-25G / H) H1H HB series Defect performance:


2. H (Except KFR-25G/H) H1 HA HB series Error codes display

Error source = PG motor response is abnormal
Display mode = 4 blinking Timer Timer light every 8 seconds
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display mode = blinking Timer light 1 time every 8 seconds
Performance precedence level = 2

Error source = Copper Temp Sensor is abnormal (indoor)
Display mode = 2 blinking Timer Timer light every 8 seconds
Performance precedence level = 3
Capillary tube

Error source = Copper Temp Sensor is abnormal (indoor)
Display mode = 1 blinking Timer light every 1 second
Performance precedence level = 4
H (Y) model air conditioner fault display:


3. H(Y) Model air conditioner Error Codes display:

Error source = PG motor response is abnormal
Display mode = 4 blinking Timer Timer light every 8 seconds
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display mode = blinking Timer light 1 time every 8 seconds
Performance precedence level = 2

Error source = Copper Temp Sensor is abnormal (indoor)
Display mode = 2 blinking Timer Timer light every 8 seconds
Performance precedence level = 3

Error source = copper temp sensor is abnormal (outdoor)
Display mode = 1 blinking Timer light every 1 second
Performance precedence level = 4


4. EAA EAD EA EC EM EY EZ EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac Error Codes:

Error source = PG motor response is abnormal
Display Mode = E4
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display Mode = E1
Performance precedence level = 2

Error source = Copper Temp Sensor is abnormal (indoor)
Display Mode = E3
Performance precedence level = 3

5. All E series except EY EZ EA EC EM EAA EAD:

Error source = PG motor response is abnormal
Display mode = 4 blinking Timer light every 8 seconds
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display mode = blinking light 1 time every 8 seconds
Performance precedence level = 2

Error source = Copper Temp Sensor is abnormal (indoor)
Display mode = 2 blinking Timer light every 8 seconds
Performance precedence level = 3


6. QA QB QD digital display series Air Conditioner Error Codes:

Error source = PG motor response is abnormal
Display Mode = E4
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display Mode = E1
Performance precedence level = 2

Error source = copper temp sensor is abnormal
Display Mode = E3
Performance precedence level = 3

Error source = over-current opacity
Display Mode = E6
Performance precedence level = 4


7. QC QQ light display series ac error codes:Aux Air Conditioner Error Codes

Error source = PG motor response is abnormal
Display mode = 4 blinking Timer light every 8 seconds
Performance precedence level = 1

Error source = plastic temp sensor is abnormal
Display mode = blinking light 1 time every 8 seconds
Performance precedence level = 2

Error source = copper temp sensor is abnormal
Display mode = 3 blinking Timer light every 8 seconds
Performance precedence level = 3

Error source = over-current opacity
Display mode = blinking Timer light 6 time every 8 seconds
Performance precedence level = 4


8. Error Codes display of 18000BTU~24000BTU wall unit series ac non-digital light displays:

Error source = PG motor response is abnormal
Display mode = blinking light 1 time every 8 seconds
Performance precedence level = 2
Presence = system shuts down

Error source = plastic temp sensor is abnormal
Display mode = 2 blinking Timer light every 8 seconds
Performance precedence level = 3
Presence = system shuts down

Error source = copper temp sensor is abnormal
Display mode = 8 blinking Timer light every 8 seconds
Performance precedence level = 4
Presence = system does not shut down


Aux Air Conditioner Error Codes

Digital light displays:

Error source = PG motor response is abnormal
Display Mode = E1
Performance precedence level = 2
Presence = system shuts down

Error source = plastic temp sensor is abnormal
Display Mode = E3
Performance precedence level = 3
Presence = system shuts down

Error source = copper temp sensor is abnormal
Display Mode = E2
Performance precedence level = 4
Presence = system does not shut down

E1: Temperature sensor of air intake defect
E2: Outdoor Coil Error Temperature Sensor
E3: Temperature sensor of indoor coil Error
E4: PG motor of indoor unit feedback Error


AUX Air Conditioner Wall Mounted Faults Codes

Self-check information: defrost signs
Self-check code of luminotron: blink one time / 1 s
Digital self-check code: Displays “DF” or defrosting indicator

Self-check information: signs of cold air protection
Self-check code of luminotron: blink one time / 3 s
Digital self-check code: Fan motor image is not running

Self-check information: room temperature sensor failure
Self-check code of luminotron: blink 2 time / 4s (blink 2 time / 8s)
Digital self-check code: E2 / (L2)

Self-check information: coiled pipe sensor failure
Self-check code of luminotron: blink 3 time / 5s (blink one time / 8s)
Digital self-check code: E3 / (L1)

Self-check information: external unit abnormality
Self-check code of luminotron: blink 4 bar / 6 s (luminous)
Digital self-check code: E4 / (E5)

Self-check information: without internal fan motor response
Self-check code of luminotron: blink 5 time / 7 s (blink 6 time / 8 s)
Digital self-check code: E5 / (L6)

Self-check information: zero crossing signal without current
Self-check code of luminotron: blink 6 time / 8s
Digital self-check code: E6

Self-check information: external feedback failure
Self-check code of luminotron: blink 7 bar / 9 s
Digital self-check code: E7

Self-check information: overheat security
Self-check code of luminotron: blink 8 time / 10 s
Digital self-check code: E8

Self-check information: water pump failure
Self-check code of luminotron: blink 9 time / 11 s
Digital self-check code: E9


Troubleshooting information book

Problem: The motor is heard operating but the air-conditioner dose does not work when the indoor unit is powered on.

Reason: Since the air-conditioner is on, it will be in working condition until you press the ON / OFF button of the remote control and the signal is well received.

Problem: The compressor stops running but the indoor fan motor keeps working when it is on cooling mode with the indoor temperature higher than the set temperature.

Reason: If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after which, the air-conditioner will automatically adjust the speed of the indoor fan you have set.

Problem: The compressor works separately on the dehumidifying mode.

Reason: The air-conditioner will automatically control the work of the compressor according to the temperature inside

Problem: Air-conditioner supplements do not work when the LED display is on.

Reason: TIMER is set with air-conditioner, it will be on hold at the position. If the TIMER setting is canceled, the air-conditioner will return to normal working state.

Problem: The compressor works immediately on the cooling and dehumidifying mode, and the indoor fan motor slows down.

Reason: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from freezing.


ALSO READ THIS