Carrier AC Error Codes and Troubleshooting
Carrier AC Error Codes and Troubleshooting
Carrier Error Codes
08 defrost mode 1
0A Defrost Mode 2
F0 low charge or refrigeration system interruption
F3 Outdoor Ambient Temp. Sensor Malfunction
F4 outdoor mid-coil Temp. sensor malfunction
F5 outdoor discharge air Temp. sensor
F7 cooling oil return cycle
E1 System High Pressure Protection
E2 Indoor Freeze Protection
E3 System Low Pressure Protection
E4 Compressor Discharge High Temp. Protection
E6 communication error between indoor and outdoor
E7 mode conflict
E8 System Overload Protection
E9 Cold Blow Protection
dd test mode
Pho pump down mode
P0 IPM left
P5 Compressor Current Protection
P6 communication error between inverter drive and main board
P7 heat sink Temp. sensor malfunction
P8 IPM over Temp. protection
P9 open contactor
PC current sensor malfunction
PD current sensor incorrect wiring protection
PA input current protection
PF inverter board ambient Temp. sensor malfunction
PL low voltage protection
PH high voltage protection
PP abnormal input AC voltage
Pu capacitor charging malfunction
H1 heating oil return cycle
H2 forced defrost
H3 Compressor Overheat Protection
H5 IPM Security
H7 compressor speed reduction
HC PFC Board Security
L9 Compressor High Voltage Protection
Lc compressor start-up failure
LD Compressor Phase Loss Protection
Take compressor standstill
LF Compressor Over-Speed Protection
A5 condenser coil inlet temp sensor sensor malfunction
A7 condenser outlet Temp. sensor malfunction
EE memory card error
N frequency limit for module circuit protection
EU frequency limit for module Temp. protection
F6 frequency limit for overload protection
F8 frequency limit for system circuit protection
F9 frequency limit for module circuit protection
FH frequency limit for freeze protection
Damaging His Majesty’s Compressor Safety
LP indoor and outdoor units are mismatched
U1 Compressor Phase Detection Malfunction
U3 Low DC Bus Voltage
dn communication error between main board and EXV
13 unit one indoor pipe outlet Temp. sensor malfunction
14 unit one indoor pipe inlet Temp. sensor malfunction
15 unit one indoor return air sensor malfunction
16 unit one mode conflict
17 Unit A Freeze Protection
23 unit B indoor pipe outlet Temp. sensor malfunction
24 unit B indoor pipe inlet Temp. sensor malfunction
25 unit B indoor return air sensor malfunction
26 unit B mode conflict
27 Unit B Freeze Protection
33 unit C indoor unit pipe outlet Temp. sensor malfunction
34 Unit C Indoor Unit Pipe Inlet Temp. Sensor Malfunction
35 unit C indoor unit return air sensor malfunction
36 unit C mode conflict
37 Unit C Freeze Protection
41 unit D communication error
42 indoor return air Temp. sensor malfunction
43 Unit D Indoor Pipe Outlet Temp. Sensor Malfunction
44 Unit D Indoor Pipe Inlet Temp. Sensor Malfunction
45 unit d indoor return air Temp. sensor malfunction
46 unit d mode conflict
47 Unit D Freeze Protection
51 unit e communication error
52 Unit E Indoor Pipe Midway Temp. Sensor Malfunction
53 Unit E Indoor Pipe Outlet Temp. Sensor Malfunction
54 Unit E Indoor Pipe Inlet Temp. Sensor Malfunction
55 unit e indoor return air Temp. sensor malfunction
56 unit E mode conflict
57 Unit E Freeze Protection
C5 jumper replacement is missing on indoor board
Refrigerator Is Freezing Everything | What To Check | How To Fix?(Opens in a new browser tab)
Problem: Indoor unit emits bad odor at start-up
Possible reasons:
Air filter dirty
Even after cleaning the filter, the output air has an odor
Solution:
Clean the air filter
Contact your service representative
Problem: When the unit is running, you hear the noise of running water
Possible Cause: This is normal and is the refrigerant flowing through the system.
Solution: no maintenance required
Problem: Indoor unit creates haze when the air conditioner is running
Possible Cause: This is normal cooling and is caused by high humidity and temperature in the room
Solution: No maintenance required. The mist should be stopped as the room is cooled and the humidity removed.
Problem: Room water leakage from indoor unit
Possible cause: Condensed water is overflowing
Solution: Check the indoor condensing drain or call your representative
Carrier Display Series AC Remote Control
Carrier Display Series AC Remote Control
Problem: Wireless remote control does not work
Possible reasons:
The daughters are dead.
The unit needs to be reset
Solution:
See the Battery Replacement section in this manual and replace the battery.
Turn off the power for the indoor unit. Remove the plug from the wall and then reinstall the plug. Restart unit
Problem: Unit / system does not work
Possible reasons:
To protect the unit on immediate restart after a stop, the system controller will delay the unit for 3 minutes before allowing the unit to start back.
The circuit breaker is tripped or the fuse has blown.
power failure
Error codes displayed
Voltage is too low
Solution:
After closing the unit, wait at least 3 minutes before attempting to restart.
Reset the circuit breaker or replace the fuse with the specified replacement fuse.
Resume operation when power is restored.
Call your service representative.
Call your service representative
Problem: cooling is not working properly
Possible reasons:
The filter is blocked by dust.
The temperature is not set properly.
A window or door is open.
The outdoor unit is interrupted.
The fan speed is very low.
Operation mode is in fan instead of cool.
Solution:
Clean the air filter.
Check temperature and reset if necessary.
Close the window or door.
Remove obstruction
Change fan speed selection.
Change the operating mode to cool or reset the unit.
Problem: heating is not working properly
Possible reasons:
The filter is blocked by dust.
The temperature is too low.
A window or door is open.
The outdoor unit is interrupted.
Solution:
Clean the air filter.
Check temperature and reset if necessary.
Close the window or door.
Clear the barrier
Problem: Unit stops during operation
Possible reasons:
Off timer is not working correctly.
Error codes displayed
Solution:
Restart operating mode.
Call your service representative.
Career Performance Series Manual PDF 1
Career Performance Series Manual PDF 2
Carrier Infinity Series AC Error Code
- Carrier Air Conditioner Error Code
- Carrier AC Error Code | Inverter AC | How to Reset a Carrier Air Conditioner
- How to Reset a Carrier Air Conditioner
- Klimaire AC Error Codes| Troubleshooting(Opens in a new browser tab)
Share and Enjoy !
Related Posts

Carrier Inverter AC Error Codes

Carrier Split Air Conditioner Error Codes