Carrier AC Error Codes and Troubleshooting

Carrier AC Error Codes and Troubleshooting

Carrier Error Codes


08 defrost mode 1


0A Defrost Mode 2


F0 low charge or refrigeration system interruption


F3 Outdoor Ambient Temp. Sensor Malfunction


F4 outdoor mid-coil Temp. sensor malfunction


F5 outdoor discharge air Temp. sensor


F7 cooling oil return cycle


E1 System High Pressure Protection


E2 Indoor Freeze Protection


E3 System Low Pressure Protection


E4 Compressor Discharge High Temp. Protection


E6 communication error between indoor and outdoor


E7 mode conflict


E8 System Overload Protection


E9 Cold Blow Protection


dd test mode


Pho pump down mode


P0 IPM left


P5 Compressor Current Protection


P6 communication error between inverter drive and main board


P7 heat sink Temp. sensor malfunction


P8 IPM over Temp. protection


P9 open contactor


PC current sensor malfunction


PD current sensor incorrect wiring protection


PA input current protection


PF inverter board ambient Temp. sensor malfunction


PL low voltage protection


PH high voltage protection


PP abnormal input AC voltage


Pu capacitor charging malfunction


H1 heating oil return cycle


H2 forced defrost


H3 Compressor Overheat Protection


H5 IPM Security


H7 compressor speed reduction


HC PFC Board Security


L9 Compressor High Voltage Protection


Lc compressor start-up failure


LD Compressor Phase Loss Protection


Take compressor standstill


LF Compressor Over-Speed ​​Protection


A5 condenser coil inlet temp sensor sensor malfunction


A7 condenser outlet Temp. sensor malfunction


EE memory card error


N frequency limit for module circuit protection


EU frequency limit for module Temp. protection


F6 frequency limit for overload protection


F8 frequency limit for system circuit protection


F9 frequency limit for module circuit protection


FH frequency limit for freeze protection


Damaging His Majesty’s Compressor Safety


LP indoor and outdoor units are mismatched


U1 Compressor Phase Detection Malfunction


U3 Low DC Bus Voltage


dn communication error between main board and EXV


13 unit one indoor pipe outlet Temp. sensor malfunction


14 unit one indoor pipe inlet Temp. sensor malfunction


15 unit one indoor return air sensor malfunction


16 unit one mode conflict


17 Unit A Freeze Protection


23 unit B indoor pipe outlet Temp. sensor malfunction


24 unit B indoor pipe inlet Temp. sensor malfunction


25 unit B indoor return air sensor malfunction


26 unit B mode conflict


27 Unit B Freeze Protection


33 unit C indoor unit pipe outlet Temp. sensor malfunction


34 Unit C Indoor Unit Pipe Inlet Temp. Sensor Malfunction


35 unit C indoor unit return air sensor malfunction


36 unit C mode conflict


37 Unit C Freeze Protection


41 unit D communication error


42 indoor return air Temp. sensor malfunction


43 Unit D Indoor Pipe Outlet Temp. Sensor Malfunction


44 Unit D Indoor Pipe Inlet Temp. Sensor Malfunction


45 unit d indoor return air Temp. sensor malfunction


46 unit d mode conflict


47 Unit D Freeze Protection


51 unit e communication error


52 Unit E Indoor Pipe Midway Temp. Sensor Malfunction


53 Unit E Indoor Pipe Outlet Temp. Sensor Malfunction


54 Unit E Indoor Pipe Inlet Temp. Sensor Malfunction


55 unit e indoor return air Temp. sensor malfunction


56 unit E mode conflict


57 Unit E Freeze Protection


C5 jumper replacement is missing on indoor board


Carrier AC Error Codes

Carrier AC Error Codes

Problem: Indoor unit emits bad odor at start-up

Possible reasons:

Air filter dirty
Even after cleaning the filter, the output air has an odor
Solution:

Clean the air filter
Contact your service representative


Problem: When the unit is running, you hear the noise of running water

Possible Cause: This is normal and is the refrigerant flowing through the system.

Solution: no maintenance required


Problem: Indoor unit creates haze when the air conditioner is running

Possible Cause: This is normal cooling and is caused by high humidity and temperature in the room

Solution: No maintenance required. The mist should be stopped as the room is cooled and the humidity removed.


Problem: Room water leakage from indoor unit

Possible cause: Condensed water is overflowing

Solution: Check the indoor condensing drain or call your representative

Carrier Display Series AC Remote Control
Carrier Display Series AC Remote Control


Problem: Wireless remote control does not work

Possible reasons:

The daughters are dead.
The unit needs to be reset
Solution:

See the Battery Replacement section in this manual and replace the battery.
Turn off the power for the indoor unit. Remove the plug from the wall and then reinstall the plug. Restart unit


Problem: Unit / system does not work

Possible reasons:

To protect the unit on immediate restart after a stop, the system controller will delay the unit for 3 minutes before allowing the unit to start back.
The circuit breaker is tripped or the fuse has blown.
power failure
Error codes displayed
Voltage is too low
Solution:

After closing the unit, wait at least 3 minutes before attempting to restart.
Reset the circuit breaker or replace the fuse with the specified replacement fuse.
Resume operation when power is restored.
Call your service representative.
Call your service representative


Problem: cooling is not working properly

Possible reasons:

The filter is blocked by dust.
The temperature is not set properly.
A window or door is open.
The outdoor unit is interrupted.
The fan speed is very low.
Operation mode is in fan instead of cool.
Solution:
Clean the air filter.
Check temperature and reset if necessary.
Close the window or door.
Remove obstruction
Change fan speed selection.
Change the operating mode to cool or reset the unit.


Problem: heating is not working properly

Possible reasons:

The filter is blocked by dust.
The temperature is too low.
A window or door is open.
The outdoor unit is interrupted.
Solution:

Clean the air filter.
Check temperature and reset if necessary.
Close the window or door.
Clear the barrier


Problem: Unit stops during operation

Possible reasons:

Off timer is not working correctly.
Error codes displayed
Solution:

Restart operating mode.
Call your service representative.