Fedders ac error codes|Troubleshooting|Heat-Pumps







Fedders ac error codes

Fedders Air Conditioner Error Codes

fedders ac error codes


Error code reason


E1 System High Pressure Protection


E2 anti-freezing protection


E4 compressor air exhaust high temp. Security


E5 AC Overload Protection


E6 indoor and outdoor units communication malfunction


E8 anti-high temp. Security


H6 Indoor Unit Motor No Response


C5 jump wire cap malfunction protection


F1 Indoor Ambient Sensor Short Circuit or Open Circuit


F2 Indoor Evaporator Sensor Circuit Open, Short Circuit


F3 outdoor ambient sensor circuit open, short circuit


F4 Outdoor Condenser Sensor Short Circuit or Open Circuit


F5 outdoor air exhaust sensor Short Circuit or Open Circuit


F6 Overload Limit / Descending Frequency


Requires current frequency greater than F8


F9 air exhaust at high requirement frequency descending


PH DC generatrix voltage is too high


U5 whole unit current test malfunction


P5 Compressor Current Overcurrent Protection


H1 Defrosting


H2 electrostatic dust protection


H3 Compressor Overload Protection


H4 system is abnormal


H5 IPM Security


HC PFC Security


H7 compressor lose step


H0 heating, anti-high temp. Declines


Lc startup failed


U1 Compressor Current Test Circuit Malfunction


EE EEPROM Malfunction


Pu capacitor charge malfunction


P7 module sensor circuit diagram


P8 Module Temp. At high security


U3 DC Bus Voltage Dip


PL Low DC Bus Voltage Protection


European Union IPM Temp. Too high a limit


U7 four-way valve unusual


U9 outdoor unit zero error detection


FH anti-freezinglimit / decreasefrequency


Fedders ac error codes




Fedders Large Split Unit (R407C)

Fedders Wall Air Conditioner-Heat Pumps-F1-F2-F3-F4-HP-C-EH-HD
Fedders Wall Air Conditioner-Heat Pumps-F1-F2-F3-F4-HP-C-EH-HD
Federation Air Conditioner Troubleshooting
Federation Air Conditioner Troubleshooting
Federation Air Conditioner Troubleshooting

Air conditioner will not operate

Possible reasons:

Cut the wall plug.
House fuse blew or circuit breaker tripped.
The unit shut down and then very quickly.
Thermostats set too low for cooling.
Solution:

Press the plug firmly into the wall outlet.
Replace fuse with time delay type or reset circuit breaker.
Wait 3 minutes before restarting.
Adjust the thermostat at low temperature

The unit does not make the air cold enough

Possible reasons:

Unit in Fan Mode.
The temperature became too high.
Room temperature below 70 ° F
Solution:

Set the mode to cool.
Set the thermostat to lower the temperature.
Cooling cannot take place until room temperature rises above 70 ° F.

Air conditioner cooling, but the room is too hot on the cooling coil behind the decorative front

Possible reasons:

Outdoor temperature below 70 ° F.
Dirty air filter restricts air.
Solution:

To defrost the coil, set the mode to the fan. Then, set the thermostat to a warm temperature.
Clean filter.

Air conditioner cooling, but too hot in the room – no ice on the cooling coil behind the decorative front

Possible reasons:

Dirty air filter restricts air.
The thermostat set is too hot.
Solution:

Clean air filter.
Set the thermostat to cool temperature.

Noise when the unit is cold

Possible reasons:

Wind speed sound.
Fan sound from melon removal system.
Window Vibration Poor Installation.
Solution:

The sound of strong wind is normal. If too loud, to reduce fan speed.
This is normal when humidity is high. Close doors, windows and registers.
Refer to the installation instructions with the installer