Pridiom AC Error Code

pridiom ac error code

Pridiom AC Error Codes
Pridiom AC Error Codes, pridiom ac error code

Note: pridiom ac error code, The above information itself applies usually to most of our air conditioners, but some are special, you can refer to the user manual for information or contact the dealer or authorized maintenance people for help.

Error code resolution


DF signal for defrosting. Self-check code of luminotron: flicker 1 bar / 1 s


Fan motor picture not running fan to protect against cold air. Flicker 1 time / 3s


E2 / (L2) room temperature sensor failure. Flicker 2 times / 4s (flicker 2 times / 8s)


Failure of E3 / (L1) coiled pipe sensor. Flicker 3 times / 5s (flicker 1 time / 8s)


E4 / (E5) abnormality of external unit. Flicker 4 times / 6s (shiny)


E5 / (L6) without feedback of internal fan motor. Flicker 5 times / 7s (flicker 6 times / 8s)


E6 cross signal without zero current. Flicker 6 times / 8 s


E7 External Response Failure. Flicker 7 times / 9 s


E8 overheat protection. Flicker 8 times / 10 s


E9 water pump failure. Flicker 9 times / 11 s


F1 communication gap


F2 Room Temp. Sensor fault


F3 Temp. Coil pipe outlet fault sensor


F4 Fan Motor Malfunction


P2 transducer module protection


P3 over current


P4 discharge temperature compressor overheat, ambient temperature overheat


Abnormal external unit of P7 DC voltage


P8 leakage or reverse valve defect


F6 Outdoor Sensor Fault


Fc compressor drive fault


Inspection and maintenance
1. According to the service conditions and operating environment, after several seasons of service (3 to 5 years) the air conditioner inside will become dirty, resulting in a decrease in operating performance. Inspection and maintenance are recommended in addition to general cleaning (air conditioner. Can be used for long periods and without worry.)
2. As an inspection and maintenance, consult your dealer or any of the business offices of the respective companies. (Service charge is required in this case.)
3. We recommend inspection and maintenance during an off season.


Selection of installation posts for outdoor unit
1. To install external unit at locations that can bear the weight of the machine and will not cause major vibration and noise;
2. Or to install the unit at locations not exposed to rain or direct sunlight, and places with good ventilation;
3. Noise generated from the generated unit will not affect neighboring locations;
4. Do not install the unit on a non-metal frame;
5. Places not to install the unit in places where the gases that may be generated can flow, leak or leak with flammable gases;
6. Pay attention to the drainage of condensed water from the base plate during operation;
7. Being to protect the air outlet from direct air.


AOS090HR 120HR Outdoor Wire Diagram

Pridiom AC Error Codes
Pridiom AC Error Codes, pridiom ac error code

AOS090HR 120HR Outdoor Wire Diagram
Remote Controller Operation and Signal Section

This remote controller is common for many types of air-conditioners in our company, we apologize that we will not apply buttons or indicators that do not apply to the units you have purchased. The LAMP button is specifically applied to the latest developed only new model instead of the normal model.


Remote Controller Operation and Signal Section

Pridiom AC Error Codes
Pridiom AC Error Codes,pridiom ac error code

Explanation The above figure shows all the indications for the purpose of explanation, but in practice only the appropriate parts are indicated. When the air-conditioner is a cooling-only model, there is a HEAT to FAT.
When turbo operation is selected, room temperature is not controlled continuously with operation. If you believe the room temperature is too cold or too hot, please cancel the turbo operation.


defrosting
When the outdoor air temperature is too low and humidity is too high, frosting occurs in the heat exchanger of the outdoor unit, which negatively impacts the efficiency of the heating performance. In such a case, the automatic defrosting function will come into play. Defrosting will stop the heating operation for 5–10 minutes.
Fans of both outdoor and indoor units are barred.
During defrosting, the external unit may generate some steam. This is caused by rapid defrosting, which is not a performance failure.
Upon completion of the defrosting process, the heating operation is resumed.