Electrolux Kelvinator AC Error Code | Troubleshooting

Electrolux Kelvinator AC Error Code

Kelvinator AC Error Codes
Kelvinator AC Error Code

Kelvinator AC Error Code

Error Codes             Problem


EE Loading EEPROM malfunction


E2 anti-freeze protection


E3 Refrigeration System Blocking / Gas Leakage


E4 Compressor High Temp Protection


E5 AC-Over Current Protection


E6 communication fault


E8 Anti-High Temperature Protection


F1 sensor, room temperature (indoor)


F2 sensor, tube temperature (indoor)


F3 sensor, ambient (outdoor)


F4 sensor, coil (outdoor)


F5 sensor, compressor discharge (outdoor)


F6 Anti-High Temperature Protection


FH anti-freeze limit, frequency drop


H1 Defrosting. This is normal. The unit is in defrosting mode and heating will be recommended soon.


H3 Compressor Overload Protection


H5 IPM Security


H6 Fan Stall, Indoor Unit


HC PFC Security


P1 compressor rated frequency-test state


P2 Compressor Maximum Frequency-Test State


P3 Compressor Medium Frequency-Test State


PH high voltage protection


PL low voltage protection


PO Compressor Minimum Frequency-Test State


LP indoor and outdoor units do not match


L3 Outdoor DC Fan Motor Malfunction


C5 jumper cap malfunction


D1 compressor off


D2 The air conditioner continues to cool or warm up during the D2 demand response event, but half of your time the electrical energy consumed by the air conditioner does not exceed 50% of the total electrical energy that is required when operating at rated capacity Consumption is in a period of half an hour.


D3 The air conditioner continues to cool or warm up during the D3 demand response event, but half of your time the electrical energy consumed by the air conditioner does not exceed 75% of the total electrical energy that is required when operating at rated capacity Consumption is in a period of half an hour.


Kelvinator AC Error Code Outdoor Meaning

Kelvinator AC Out Door Error Codes
Kelvinator AC Error Code

E2 Freeze Protection


H5 IPM Security


E5 Overcrout Protection


EE EEPROM read and write fault


PL low voltage protection


PH high voltage protection


HC PFC Overcurrent Protection


LP mismatch of indoor and outdoor unit models


F3 malfunction of outdoor ambient temperature sensor


F4 external pipe temperature sensor malfunction


F5 malfunction of outdoor discharge temperature sensor


E6 communication malfunction


E3 low pressure protection (refrigerant leakage)


U7 impermeability of 4-way valve


E8 over-load protection


E4 discharge temperature protection


H3 overload protection


L9 Lightning Protection


Kelvinator AC Error Code Troubleshooting

The air conditioner is not serviceable to the user. Incorrect repair can cause an electric shock or fire, so please contact an authorized service center for professional repairs. The following checks before contact can save you time and money.


Issue: Unit does not operate
Reason: The unit does not turn on immediately after shutdown. This is to protect the unit. You should wait about 3 minutes.


Issue: smells are emitted
Reason:
1. Some odors may be emitted from the indoor unit. This is the result of the room odor (such as furniture, tobacco, etc.) taken in the air conditioner.
2. If sulfur remains, consult the authorized service center for cleaning.


Issue: “flowing water” noise
Reason:Noise flowing like water is the refrigerant flowing inside the unit.


Issue:Haze is emitted in COOL mode
Reason:During cooling operation, a thin mist can be seen emitting from the indoor unit due to the high temperature and humidity of the room. After a period of time, the mist will disappear when room temperature decreases and humidity decreases.


Issue: Noise
Reason: This is the sound of friction caused by expansion and / or contraction of the panel or other parts due to temperature changes.


Issue:The unit cannot be started
Reason:
1. Is the electricity disconnected?
2. Is the power plug loose? (if applicable )
3. Is the circuit protection device closed?
4. Is the voltage high or low? (Tested by professionals)
5. Used correctly at the right time?


Issue: cooling / heating effect is bad
Reason:
1. Is the temperature setting reasonable?
2. Is the inlet or outlet blocked?
3. Is the filter dirty?
4. Is the window or door open?
5. Is the low fan speed set?
6. Are there sources of heat in the room?


Issue: The remote control does not transmit the signal
Reason:
1. Check if the unit has magnetic or electrical interference that may affect the operation of the remote control. In this case, take out the plug and reinstall it.
2. Is the remote controlled or interrupted within its operating range? Check the condition of the batteries and replace them if necessary.
3. Check if the remote control is damaged.


Issue:Water leakage of indoor unit
Reason:
1. Humidity is high.
2. Condensed water overflow.
3. Drain hose is loose or obstructed.


Issue:Water leakage of external unit
Reason:
1. During cooling operation, the water condenses around the pipe and connection joints.
2. During the defrosting operation, the molten water flows.
3. During the heating operation, the water on the heat exchanger dries up.


Issue: Noise from indoor unit.
Reason:
1. Noise emits when the fan or compressor relay is switched on or off.
2. When defrosting operation is started or stopped, there is a sound of refrigerant flowing backwards.


Issue: Indoor unit cannot blow air
Reason:
1. In HEAT mode, when the temperature of the indoor heat exchanger is very low, the air flow is stopped to prevent cold air. (Within 2 minutes)
2. In HEAT mode, when the outdoor temperature is low or humidity is high, frost will be formed on the external heat exchanger. The unit will automatically defrost and the indoor unit will stop blowing air for 3–12 minutes.
3. During defrosting operation, water or vapor may be emitted.
4. In DRY mode, the indoor fan will stop blowing air for 3–12 minutes to protect the condenser water from evaporating again.


Issue: Moisture at air outlet
Reason: If the unit is operated at high humidity for a long time, moisture will be generated on the air outlet grill and then drip off.


Issue: H1-Defrosting
Reason: This is normal. The unit is in defrosting mode and heating will be recommended soon.


Issue: E3-Low Pressure Warning
Reason: Your air conditioner has lost refrigerant. Contact your installer to check for possible leaks.
The pressure in the refrigeration system is low and can result in unit breakdown. Ask a certified installer to control it. If any one of the following conditions occurs, immediately stop all operations, disconnect the power supply, and contact authorized personnel.
01. A harsh sound occurs during har operation.
02. Strong odors are emitted during operation.
03. Water is leaking from the King unit.
04. Circuit breaker makes frequent trips.
05. Water or other liquid is divided into units.
06. Power cord and power plug overheating.