Electrolux Kelvinator AC Error Code | Troubleshooting
Electrolux Kelvinator AC Error Code

Kelvinator AC Error Code
Error Codes Problem
EE Loading EEPROM malfunction
E2 anti-freeze protection
E3 Refrigeration System Blocking / Gas Leakage
E4 Compressor High Temp Protection
E5 AC-Over Current Protection
E6 communication fault
E8 Anti-High Temperature Protection
F1 sensor, room temperature (indoor)
F2 sensor, tube temperature (indoor)
F3 sensor, ambient (outdoor)
F4 sensor, coil (outdoor)
F5 sensor, compressor discharge (outdoor)
F6 Anti-High Temperature Protection
FH anti-freeze limit, frequency drop
H1 Defrosting. This is normal. The unit is in defrosting mode and heating will be recommended soon.
H3 Compressor Overload Protection
H5 IPM Security
H6 Fan Stall, Indoor Unit
HC PFC Security
P1 compressor rated frequency-test state
P2 Compressor Maximum Frequency-Test State
P3 Compressor Medium Frequency-Test State
PH high voltage protection
PL low voltage protection
PO Compressor Minimum Frequency-Test State
LP indoor and outdoor units do not match
L3 Outdoor DC Fan Motor Malfunction
C5 jumper cap malfunction
D1 compressor off
D2 The air conditioner continues to cool or warm up during the D2 demand response event, but half of your time the electrical energy consumed by the air conditioner does not exceed 50% of the total electrical energy that is required when operating at rated capacity Consumption is in a period of half an hour.
D3 The air conditioner continues to cool or warm up during the D3 demand response event, but half of your time the electrical energy consumed by the air conditioner does not exceed 75% of the total electrical energy that is required when operating at rated capacity Consumption is in a period of half an hour.
Kelvinator AC Error Code Outdoor Meaning

E2 Freeze Protection
H5 IPM Security
E5 Overcrout Protection
EE EEPROM read and write fault
PL low voltage protection
PH high voltage protection
HC PFC Overcurrent Protection
LP mismatch of indoor and outdoor unit models
F3 malfunction of outdoor ambient temperature sensor
F4 external pipe temperature sensor malfunction
F5 malfunction of outdoor discharge temperature sensor
E6 communication malfunction
E3 low pressure protection (refrigerant leakage)
U7 impermeability of 4-way valve
E8 over-load protection
E4 discharge temperature protection
H3 overload protection
L9 Lightning Protection
Kelvinator AC Error Code Troubleshooting
The air conditioner is not serviceable to the user. Incorrect repair can cause an electric shock or fire, so please contact an authorized service center for professional repairs. The following checks before contact can save you time and money.
Issue: Unit does not operate
Reason: The unit does not turn on immediately after shutdown. This is to protect the unit. You should wait about 3 minutes.
Issue: smells are emitted
Reason:
1. Some odors may be emitted from the indoor unit. This is the result of the room odor (such as furniture, tobacco, etc.) taken in the air conditioner.
2. If sulfur remains, consult the authorized service center for cleaning.
Issue: “flowing water” noise
Reason:Noise flowing like water is the refrigerant flowing inside the unit.
Issue:Haze is emitted in COOL mode
Reason:During cooling operation, a thin mist can be seen emitting from the indoor unit due to the high temperature and humidity of the room. After a period of time, the mist will disappear when room temperature decreases and humidity decreases.
Issue: Noise
Reason: This is the sound of friction caused by expansion and / or contraction of the panel or other parts due to temperature changes.
Issue:The unit cannot be started
Reason:
1. Is the electricity disconnected?
2. Is the power plug loose? (if applicable )
3. Is the circuit protection device closed?
4. Is the voltage high or low? (Tested by professionals)
5. Used correctly at the right time?
Issue: cooling / heating effect is bad
Reason:
1. Is the temperature setting reasonable?
2. Is the inlet or outlet blocked?
3. Is the filter dirty?
4. Is the window or door open?
5. Is the low fan speed set?
6. Are there sources of heat in the room?
Issue: The remote control does not transmit the signal
Reason:
1. Check if the unit has magnetic or electrical interference that may affect the operation of the remote control. In this case, take out the plug and reinstall it.
2. Is the remote controlled or interrupted within its operating range? Check the condition of the batteries and replace them if necessary.
3. Check if the remote control is damaged.
Issue:Water leakage of indoor unit
Reason:
1. Humidity is high.
2. Condensed water overflow.
3. Drain hose is loose or obstructed.
Issue:Water leakage of external unit
Reason:
1. During cooling operation, the water condenses around the pipe and connection joints.
2. During the defrosting operation, the molten water flows.
3. During the heating operation, the water on the heat exchanger dries up.
Issue: Noise from indoor unit.
Reason:
1. Noise emits when the fan or compressor relay is switched on or off.
2. When defrosting operation is started or stopped, there is a sound of refrigerant flowing backwards.
Issue: Indoor unit cannot blow air
Reason:
1. In HEAT mode, when the temperature of the indoor heat exchanger is very low, the air flow is stopped to prevent cold air. (Within 2 minutes)
2. In HEAT mode, when the outdoor temperature is low or humidity is high, frost will be formed on the external heat exchanger. The unit will automatically defrost and the indoor unit will stop blowing air for 3–12 minutes.
3. During defrosting operation, water or vapor may be emitted.
4. In DRY mode, the indoor fan will stop blowing air for 3–12 minutes to protect the condenser water from evaporating again.
Issue: Moisture at air outlet
Reason: If the unit is operated at high humidity for a long time, moisture will be generated on the air outlet grill and then drip off.
Issue: H1-Defrosting
Reason: This is normal. The unit is in defrosting mode and heating will be recommended soon.
Issue: E3-Low Pressure Warning
Reason: Your air conditioner has lost refrigerant. Contact your installer to check for possible leaks.
The pressure in the refrigeration system is low and can result in unit breakdown. Ask a certified installer to control it. If any one of the following conditions occurs, immediately stop all operations, disconnect the power supply, and contact authorized personnel.
01. A harsh sound occurs during har operation.
02. Strong odors are emitted during operation.
03. Water is leaking from the King unit.
04. Circuit breaker makes frequent trips.
05. Water or other liquid is divided into units.
06. Power cord and power plug overheating.