LG AC Error Code Solution Inverter Air Conditioner The “unit” digit of the fault code is shown by the power that has the following symbol. It is usually red, but on some models it is green. If there is a malfunction in an LG universal unit, a two-digit number will appear on the display led by the remote controllers. If the unit does not have a remote controller, the fault will be displayed using the LED in front of the indoor unit.

Error Indicator: 

LG AC Error Code Solution Inverter Air Conditioner, The function provides self-diagnosis and displays error codes when there is any trouble.
Error codes are displayed as a CH **, and / or fascia display on the wired remote of the indoor unit. In addition, the code is indicated through the LED of the external unit control board.
If more than two problems occur simultaneously, a lower number of error codes are displayed first.
After the error occurs, if the error is released, the error LED is also released simultaneously. Lg Tower Air Conditioner

LG Air Conditioner Error Codes Solution |Inverter Air Conditioner Content:

  • LG Split Type AC Error Codes
  • LG Multi Type AC Error Codes
  • LG Floor Standing AC Error Codes
  • LG Ceiling Cassette AC Error Codes
  • LG AC Universal Split Fault Codes
  • LG PTAC AC Error Codes
  • LG Portable Air Conditioner Error Codes

LG Split Type AC Error Codes

Lg-Air-Conditioner-Error-Code

Indoor Unit Faults
Error code Cause
C1 or CH1 indoor temperature sensor open or closed circuit.
C2 or CH2 outdoor temperature sensor open or closed circuit.
C4 or CH4 heat sink temperature sensor open or closed circuit.
C5 or CH5  communication between indoor and outdoor units.
C6 or CH6  excessive current in the inverter DC power circuit.
C7 or CH7  excessive compressor current
C8 or CH8  indoor fan does not rotate.
C9 or CH9 Outdoor fan does not rotate.
C10orCH10 Compressor’s thermometer temperature control split system faulty (a short circuit or breakdown);
CH12 coil sensor defective
CA  Discharge temp greater than 1 ° C 2. Defective discharge thermistor
CC  EEPROM error
CD Inverter module error
PO  system in power mode – not a fault
Lo system in power mode – not a fault

LG Multi Type AC Error Codes

 

LG AC Error Code Solution|Inverter Air Conditioner

LG AC Error Code Solution| Inverter Air Conditioner

Error code = 01
Content = Air Sensor (Open / Short)
Error Case = Open / Short Circuit
Indoor position = closed

Error code = 02
Material = Inlet Pipe Sensor
Error Case = Open / Short Circuit
Indoor position = closed

Error code = 03
Content = Communication (Indoor Wired R / Control)
Case of error = poor communication
Indoor position = closed

Error code = 04
Material = drain pump / float switch
Case of error = float switch open circuit (high level water alarm)
Indoor position = closed

Error code = 05
Content = Communication (Indoor Outdoor)
Case of error = poor communication
Indoor position = closed

Error code = 06
Content = outlet pipe sensor
Error Case = Open / Short Circuit
Indoor position = closed

Error Code = 07
Content = Different Operation Modes
Error case = Indoor units set to different operation modes
Indoor position = closed

Error code = hl
Content = High Limit (Float Switch)
Case of error = same as code 04, float switch open circuit
Indoor position = closed

Error code = cl
Content = Child Lock Function Selected
Case of error = no error, press the timer and min button simultaneously for 3 seconds to toggle on / off
Indoor position = on

Error code = 21
Content = IPM defect (currently compressor)
LED01G = 2 times (red)
LED02G = 1 time (green)
Error case = Compressor malfunction, IPM fault
External position = closed

Error code = 22
Content = CT2 (Maximum current)
LED01G = 2 times (red)
LED02G = 2 times (green)
Case of error = current is 14 A.
External position = closed

Error code = 23
Content = DC Link Low Voltage.
LED01G = 2 times (red)
LED02G = 3 times (green)
Case of error = DC link volt. 140 V
External position = closed

Error code = 24
Material = Low / High Pressure
LED01G = 2 times (red)
LED02G = 4 times (green)
Error case = low / high press switch open
External position = closed

Error code = 25
Material = AC Low / AC High Voltage.
LED01G = 2 times (red)
LED02G = 5 times (green)
Case of error = abnormal AC volt. Input.
External position = closed

Error code = 26
Content = DC Compressor Status
LED01G = 2 times (red)
LED02G = 6 times (green)
External position = closed

Error code = 27
Material = PSC defect (reactor)
LED01G = 2 times (red)
LED02G = 7 times (green)
External position = closed

Error code = 28
Content = DC Link High Voltage
LED01G = 2 times (red)
LED02G = 8 times (green)
Case of error = closed
External position = closed

Error code = 32
Content = discharge pipe temp. High (inv)
LED01G = 3 times (red)
LED02G = 2 times (green)
Case of error = closed
External position = closed

Error code = 33
Content = discharge pipe temp. High (cons)
LED01G = 3 times (red)
LED02G = 3 times (green)
Case of error = closed
External position = closed

Error code = 40
Content = CT circuit
LED01G = 4 times (red)
LED02G = (Green)
Error case = CT circuit malfunction
External position = closed

Error code = 41
Material = D-pipe sensor INV. (Open / low)
LED01G = 4 times (red)
LED02G = 1 time (green)
Case of error = open / short circuit.
External position = closed

Error code = 44
Content = Air Sensor (Open / Short)
LED01G = 4 times (red)
LED02G = 4 times (green)
Case of error = open / short circuit.
External position = closed

Error code = 45
Content = Condensed. Pipe Sensor (Open / Short)
LED01G = 4 times (red)
LED02G = 5 times (green)
Case of error = open / short circuit.
External position = closed

Error code = 46
Material = Suction Pipe Sensor (Open / Short)
LED01G = 4 times (red)
LED02G = 6 times (green)
Error Case = Open / Short Circuit
External position = closed

Error code = 47
Content = D-pipe sensor cons. (Open / low)
LED01G = 4 times (red)
LED02G = 7 times (green)
Error Case = Open / Short Circuit
External position = closed

Error code = 48
Material = D-pipe and air sensor (open)
LED01G = 4 times (red)
LED02G = 8 times (green)
Error Case = Dual Sensor Unplugged
External position = closed

Error code = 51
Content = Over capacity
LED01G = 5 times (red)
LED02G = 1 time (green)
Error case = Overload connection
External position = closed

Error code = 52
Content = Communication error (main mic sub sub micom)
LED01G = 5 times (red)
LED02G = 2 times (green)
Case of error = poor / loss of communication
Outdoor position = 0ff

Error code = 53
Material = Communication error (indoor outdoor)
LED01G = 5 times (red)
LED02G = 3 times (green)
Case of error = poor / loss of communication
External position = closed

Error code = 54
Material = external 3-phase power supply reverse phase / missing phase
LED01G = 5 times (red)
LED02G = 4 times (green)
Error Case = Wiring Wrong
External position = closed

Error code = 60
Contact = EEPROM check even
LED01G = 6 times (red)
LED02G = (Green)
Case of error = check even miss-match
External position = closed

Error code = 61
Content = Condensed. Pipe sensor temp. High
LED01G = 6 times (red)
LED02G = 1 time (green)
Case of error = cooperation. Temporary. High
External position = closed

Error code = 62
Content = Heat sink sensor temp. High
LED01G = 6 times (red)
LED02G = 2 times (green)
Case of Error = Heat Sink Temp. High
External position = closed

Error code = 63
Content = Condensed. Pipe sensor temp. Less
LED01G = 6 times (red)
LED02G = 2 times (green)
Case of error = cooperation. Temporary. Less
External position = closed

Error code = 65
Material = Heat Sink Sensor (Open / Short)
LED01G = 6 times (red)
LED02G = 5 times (green)
Error Case = Open / Short Circuit
External position = closed

Error code = 67
Content = Outdoor BLDC Fan Locke
LED01G = 6 times (red)
LED02G = 7 times (green)
Case of error = fan motor / circuit problem
External position = closed

Error code = 105
Compound = compound. Error (main board fan board)
LED01G = 6 times (red)
LED02G = 5 times (green)
Case of error = poor / loss of communication
External position = closed